Boiler not igniting: testing ignition and flame sensing

Boiler not igniting or locking out once lit? Test the spark, the electrode gap and the flame current, and tell an ignition fault from a flame sensing fault.

What it does

The spark lights the gas. Then the PCB has to see the flame or it shuts the gas off. It puts a voltage on the sense electrode, and a flame conducts a tiny DC current from the electrode to the burner, which is earthed. It's measured in microamps. Some boilers use one electrode for both jobs.

Symptoms when it fails

How to test it

  1. Read the flame signal in the service menu if the boiler has one. No leads needed.
  2. Isolate power and gas. Lock off and prove dead (chapter 1).
  3. Look at the electrodes. Cracked ceramic, worn or corroded tips, carbon, a wrong gap, a damaged lead or cap.
  4. Check the gap against the manufacturer's figure. Set it with the electrode out, never by bending it in place.
  5. No spark: continuity of the lead and electrode, then the ignition unit's supply. On many boilers the spark comes from the PCB.
  6. Sparks with gas on but won't light: suspect the gas supply or the gas valve (4.4).
  7. Live Flame current. Meter on µA DC in series in the sense lead, only where the manufacturer allows it. Red lead in the µA socket, and back afterwards.
  8. Live Prove the flame sensing. Burner lit, turn the gas off at the appliance valve. Pass: it locks out within 60 seconds, or within 2 minutes of relight tries, and doesn’t relight when the gas is back. One that keeps sparking and lights normally once the gas is back also passes. Wait 2 minutes before you open the valve, then reset and watch it light.
Ignition and flame sensing. A mesh burner hangs from the burner door with short flames on its surface. Two spark electrodes come through the door beside it with a gap between their tips. A separate flame sense electrode on the other side has its tip in the flame. A tiny DC current flows from the sense electrode through the flame to the burner and back to the PCB through earth.

The spark jumps the gap. The flame then carries a tiny DC current from the sense electrode to the earthed burner, and back to the PCB.

Typical readings

Gaps and minimums vary by model. Set to the figure for the boiler in front of you.

Electrode gap
3 to 5 mmThe usual spark gap.
Flame current · µA DC · burner lit
5 to 30 µAUsual for a good flame.
Under the minimumThe minimum is often 1 to 1.5 µA. Electrode, then earth.
Service menu flame value
VariesOften display units, not µA. Read it against the boiler’s own table.
Out of the burner: the spark pair (left) and its gap, and the flame sense electrode (right).

Illustration. Out of the burner: the spark pair (left) and its gap, and the flame sense electrode (right).

Common failures

Cracked ceramic. The spark tracks to earth inside the boiler instead of across the gap.

Worn, bent or coated tip. Weak spark, low flame current.

Lead or cap damaged. Damp or cracked. Sparks to the case.

Poor burner earth. Low flame current with a good flame.

Live and neutral swapped. Some boilers can’t prove the flame. Others run as normal. Check polarity (chapter 2).

Free guide

Get Fault Finding Basics as a PDF

This lesson is part of Fault Finding Basics, our free 26-page guide: safe isolation, your meter, how a combi works and the five tests that find most faults. Add your email and it comes straight over.

Send me the guide

Want every test? The Flint Field Guide has all 56 chapters with a video for every test. £97 once, updates included.

All fault finding lessons

For competent, Gas Safe registered engineers. Isolate and prove dead before any electrical test. Always work to the manufacturer's instructions and the current standards, and check every figure against the appliance data badge and manual.