Home Fault finding Y plan wiring diagram
Fault finding
Y plan wiring diagram
A three-port mid-position valve shares the boiler between heating and hot water. Know which wire is live when, and the valve tests itself.
Y plan: one mid-position valve
A three-port valve shares the boiler between heating and hot water. Know which wire is live when, and the valve tests itself.

How it works: the lives only. Neutrals and earths left off, apart from the valve's blue. Page 19 shows the same circuit wired at a wiring centre.
Which wire does what
| White | From the room stat, live when heating is called. |
| Grey | Live when hot water is off on the timer, or the cylinder stat is satisfied. |
| Orange | Out from the end switch. Live once port A is open. Feeds boiler and pump. |
| Blue | Motor neutral. |
| Green/yellow | Earth. |
What the valve does
| Hot water only | Valve not powered, rests on port B. Cylinder stat terminal 1 feeds boiler and pump direct. |
| Heating only | White and grey live. Drives to port A. Orange live. |
| Both | White live, grey dead. Stops in mid position, both ports open. |
Force tests: prove the valve
Isolate, make each link at the wiring centre, then power up. Put the wiring back as you found it.
- Live Heating only. Grey and white to permanent live. Valve drives to A, boiler and pump run, port A warms.
- Live Hot water only. Grey and white made safe, cylinder stat common to live, stat calling. Port B warms.
- Live Both. Grey made safe, white to live. Valve stops in mid position, both ports warm.
All three pass: the valve is fine. Look at the stats and the programmer.
Common faults
Valve lets by. Radiators warm on hot water only. Debris stops port A sealing.
Seized ball or paddle. No heating or no hot water.
End switch. White live, valve open, orange dead.
Synchron motor. White lifted, ohms white to N: typically 2,000 to 2,500 Ω, or the manufacturer’s figure for that motor. OL or far out is faulty.
Ghost voltage on white. A stray voltage with nothing calling can fire the boiler. Find the faulty control first. A trade tip, not a rule: some engineers fit a suppressor from orange to N as a last resort.
Y plan at the wiring centre
On a real job nothing is wired control to control. Every cable runs back to a wiring centre and lands on a numbered terminal.
Example: terminal numbers vary by wiring centre, follow the label in the box.

Every cable to the wiring centre. The same circuit as page 18, wired the way you'll find it. Neutrals share terminal 2 and earths share terminal 3.
What lands where
| 1 L | Fused spur live, programmer L, boiler permanent live. |
| 2 N | Spur, programmer, room stat 2 (if it has one), valve blue, pump, boiler. |
| 3 E | Spur, valve green/yellow, pump, boiler. |
| 4 | Programmer CH ON (4) to room stat 1. |
| 5 | Room stat 3 to the valve white. |
| 6 | Programmer HW ON (3) to cylinder stat C. |
| 7 | Programmer HW OFF (1), cylinder stat 2, valve grey. |
| 8 | Cylinder stat 1, valve orange, boiler switched live, pump live. |
On the job
Read the box first. Wiring centres don't all number the same way. Use the label inside the lid, or trace each cable back to its control.
Room stat 2 goes to neutral, if the stat has one. Terminal 2 on the stat, terminal 2 at the wiring centre. Two-wire and battery stats have no neutral: they only switch the live, so connect just the stat’s two terminals and follow its instructions.
The force tests on page 18 are done here. Isolated, lift the white and grey off 5 and 7 and land them on 1, then power up. Put every core back where it came from.
Boiler wiring varies. Some boilers want a permanent live as well as the switched live, and some drive the pump themselves. Follow the boiler’s manual for its own terminals.
Free guide
Get Fault Finding Basics as a PDF
This lesson is part of Fault Finding Basics, our free 26-page guide: safe isolation, your meter, how a combi works and the five tests that find most faults. Add your email and it comes straight over.
Send me the guideWant every test? The Flint Field Guide has all 56 chapters with a video for every test. £97 once, updates included.
For competent, Gas Safe registered engineers. Isolate and prove dead before any electrical test. Always work to the manufacturer's instructions and the current standards, and check every figure against the appliance data badge and manual.